Cyclohexanethiol | CAS 1569-69-3 | ||
C6H11SH | RTECS GV7525000 | ||
Synonyms & Trade Names Cyclohexylmercaptan, Cyclohexylthiol |
DOT ID & Guide 3054 131 |
Exposure Limits |
NIOSH REL: C 0.5 ppm (2.4 mg/m3) [15-minute] | ||
OSHA PEL: none | |||
IDLH N.D. | Conversion 1 ppm = 4.75 mg/m3 |
Physical Description Colorless liquid with a strong, offensive odor. |
|||
MW: 116.2 |
BP: 316°F |
FRZ: -181°F |
Sol: Insoluble |
VP: 10 mmHg |
IP: ? |
|
Sp.Gr: 0.98 |
Fl.P: 110°F |
UEL: ? |
LEL: ? |
|
Class II Combustible Liquid: Fl.P. at or above 100�F and below 140�F. | |||
Incompatibilities & Reactivities Oxidizers, reducing agents, strong acids, alkali metals |
Measurement Methods None available |
Personal Protection & Sanitation Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: No recommendation Provide: Eyewash, Quick drench |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap flush immediately Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations
NIOSH Up to 5 ppm: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)/(APF = 10) Any supplied-air respirator Up to 12.5 ppm: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode/(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s) Up to 25 ppm: (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)/(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)/(APF = 50) Any self-contained breathing apparatus with a full facepiece/(APF = 50) Any supplied-air respirator with a full facepiece Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode/(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister/Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, skin, respiratory system; headache, dizziness, lassitude (weakness, exhaustion), nausea, vomiting, convulsions; cough, wheezing, laryngitis, dyspnea (breathing difficulty) | |
Target Organs
Eyes, skin, respiratory system, central nervous system |
See also: INTRODUCTION |