Cyhexatin | CAS 13121-70-5 | ||
(C6H11)3SnOH | RTECS WH8750000 | ||
Synonyms & Trade Names TCHH, Tricyclohexylhydroxystannane, Tricyclohexylhydroxytin, Tricyclohexylstannium hydroxide, Tricyclohexyltin hydroxide |
DOT ID & Guide |
Exposure Limits |
NIOSH REL: TWA 5 mg/m3 | ||
OSHA PEL�: TWA 0.32 mg/m3 [0.1 mg/m3 (as Sn)] | |||
IDLH 80 mg/m3 [25 mg/m3 (as Sn)] | Conversion |
Physical Description Colorless to white, nearly odorless, crystalline powder. [insecticide] |
|||
MW: 385.2 |
BP: 442°F (Decomposes) |
MLT: 383°F |
Sol: Insoluble |
VP: 0 mmHg (approx) |
IP: NA |
|
Sp.Gr: ? |
Fl.P: NA |
UEL: NA |
LEL: NA |
|
Incompatibilities & Reactivities Strong oxidizers, ultraviolet light |
Measurement Methods NIOSH 5504 |
Personal Protection & Sanitation Skin: Prevent skin contact Eyes: No recommendation Wash skin: When contaminated Remove: When wet or contaminated Change: Daily |
First Aid (See procedures) Eye: Irrigate immediately Skin: Soap wash immediately Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations
OSHA Up to 3.2 mg/m3: (APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s) in combination with a dust and mist filter/(APF = 10) Any supplied-air respirator Up to 8 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode/(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s) in combination with a dust and mist filter Up to 16 mg/m3: (APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter/(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having a high-efficiency particulate filter/(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter/(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode/(APF = 50) Any self-contained breathing apparatus with a full facepiece/(APF = 50) Any supplied-air respirator with a full facepiece Up to 80 mg/m3: (APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode/(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having a high-efficiency particulate filter/Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, skin absorption, ingestion, skin and/or eye contact | |
Symptoms Irritation eyes, skin, respiratory system; headache, dizziness; sore throat, cough; abdominal pain, vomiting; skin burns, pruritus; in animals: liver, kidney damage | |
Target Organs
Eyes, skin, respiratory system, liver, kidneys |
See also: INTRODUCTION |