Manganese compounds and fume (as Mn) | CAS 7439-96-5 (metal) | ||
Mn (metal) | RTECS OO9275000 (metal) | ||
Synonyms & Trade Names Manganese metal: Colloidal manganese, Manganese-55 Synonyms of other compounds vary depending upon the specific manganese compound. |
DOT ID & Guide |
Exposure Limits |
NIOSH REL*: TWA 1 mg/m3 ST 3 mg/m3 [*Note: Also see specific listings for Manganese cyclopentadienyl tricarbonyl, Methyl cyclopentadienyl manganese tricarbonyl, and Manganese tetroxide.] | ||
OSHA PEL*: C 5 mg/m3 [*Note: Also see specific listings for Manganese cyclopentadienyl tricarbonyl and Methyl cyclopentadienyl manganese tricarbonyl.] | |||
IDLH 500 mg/m3 (as Mn) | Conversion |
Physical Description A lustrous, brittle, silvery solid. |
|||
MW: 54.9 |
BP: 3564°F |
MLT: 2271°F |
Sol: Insoluble |
VP: 0 mmHg (approx) |
IP: NA |
|
Sp.Gr: 7.20 (metal) |
Fl.P: NA |
UEL: NA |
LEL: NA |
|
Metal: Combustible Solid | |||
Incompatibilities & Reactivities Oxidizers [Note: Will react with water or steam to produce hydrogen.] |
Measurement Methods NIOSH 7300; OSHA ID121, ID125G |
Personal Protection & Sanitation Skin: No recommendation Eyes: No recommendation Wash skin: No recommendation Remove: No recommendation Change: No recommendation |
First Aid (See procedures) Breathing: Respiratory support Swallow: Medical attention immediately |
Respirator Recommendations
NIOSH Up to 10 mg/m3: (APF = 10) Any dust and mist respirator except single-use and quarter-mask respirators^/(APF = 10) Any supplied-air respirator Up to 25 mg/m3: (APF = 25) Any supplied-air respirator operated in a continuous-flow mode/(APF = 25) Any powered, air-purifying respirator with a dust and mist filter^ Up to 50 mg/m3: (APF = 50) Any air-purifying, full-facepiece respirator with a high-efficiency particulate filter/(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode/(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter/(APF = 50) Any self-contained breathing apparatus with a full facepiece/(APF = 50) Any supplied-air respirator with a full facepiece Up to 500 mg/m3: (APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode Emergency or planned entry into unknown concentrations or IDLH conditions: (APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode/(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus Escape: (APF = 50) Any air-purifying, full-facepiece respirator with a high-efficiency particulate filter/Any appropriate escape-type, self-contained breathing apparatus |
|
Exposure Routes inhalation, ingestion | |
Symptoms Parkinson's; asthenia, insomnia, mental confusion; metal fume fever: dry throat, cough, chest tightness, dyspnea (breathing difficulty), rales, flu-like fever; low-back pain; vomiting; malaise (vague feeling of discomfort); lassitude (weakness, exhaustion); kidney damage | |
Target Organs
respiratory system, central nervous system, blood, kidneys |
See also: INTRODUCTION |