AIR-LINE RESPIRATORS [BACK]  [NEXT]

Duo-Twin™ Respirators and Duo-Flo™ Respirators 

Duo-TwinRespirators

MSA offers Duo-Twin Respirators in both

 Constant-Flow and Pressure-Demand versions.

Constant-Flow respirators are normally used where an ample air supply is available, such as that provided by an

air compressor. Pressure-

Demand respirators are

generally used where only

compressed-air cylinders

are available. MSA Duo-Twin

Respirators feature air purifying cartridges, which

also protect against a variety of contaminants.

If the air supply should ever fail on the Constant-Flow unit, the user is automatically protected by the air-purifying cartridge.

This product is popular in the pharmaceutical, chemical, petrochemical, and nuclear industries. The unique D/PD switchable exhalation valve, standard on Pressure-Demand

models, also makes these units especially well-suited for

abatement work. This MSA respirator should not be used in

atmospheres containing less than 19.5% oxygen.

NIOSH approved.

Duo-Twin Respirator

Duo-FloRespirators

MSA offers Duo-Flo

Respirators in both

Constant-Flow and

Pressure-Demand

versions. Constant-Flow

Respirators are normally

used where an ample air

supply is available, such as that

provided by an air compressor.

Pressure-Demand respirators

are generally used where only

compressed-air cylinders are    available. Duo-Flo Respirators use                                 Constant-                                                                         Flow Duo-Flo Respirator

the MSA Ultra Filter, a compact

round filter cartridge that has a

large effective filter area to provide

low-breathing resisting. This

cartridge has a P100 classification.

Duo-Flo Respirators are popular in the

pharmaceutical, chemical, petrochemical,

and nuclear industries. The                       Ultra Filter P100 cartridge

unique D/PD switchable exhalation

valve, standard on Pressure-Demand

respirators, also makes these units

especially well-suited for abatement work. This MSA respirator

should not be used in atmospheres containing less than 19.5%

oxygen. NIOSH approved

Replacement Cartridges for Duo-Flo
Respirators

Round Ultra FIlter Cartridge, box of 6    10010420
Round Ultra Filter Cartridge, box of 6   10010421

Duo-TwinRespirators

Complete Assemblies*

Complete with facepiece, breathing tube, adapter assembly/regulator, web belt and Foster

steel plug and socket assembly

Constant Flow Duo-Twin Respirator  

484087

Pressure-Demand Duo-Twin Respirator  

484441

Switchable D/PD Exhalation Valve

Allows the Pressure Demand Duo-Flo and Duo-Twin Respirators to be approved for

continuous use while in either the air-line or air-purifying mode of operation.

Switchable Exhalation Valve for PD Duo-Flo Respirator  

486282

Duo-Twin Plug

Allows conversion of a Duo-Twin facepiece to a Twin-Cartridge Respirator.

Duo-Twin Plug  

486637

* Cartridges must be ordered separately. See page 13 for ordering information.

 

Duo-Flo Respirators

Complete Assemblies (one P100 Ultra Filter is included)

Constant Flow Duo-Flo Respirator w/full-face Ultravue Facepiece  

466095

Constant Flow Duo-Flo Respirator w/half-mask Comfo Facepiece  

466097

Pressure-Demand Duo-Flo Respirator w/full-face Ultravue Facepiece  

484378

Ass

Pressure-Demand Regulator Assemblies (Belt-Mounted)
for Duo-Twin and Duo-Flo Units

The Pressure-Demand Regulator maintains air flow at a minimum of 1.0 inches of water positive

pressure to the facepiece. Flow stops during exhalation when the Pressure-Demand valve opens

at approximately 1.5 inches of water positive pressure. The regulator has an integral belt clip,

which can be easily adjusted along the support belt for comfortable positioning.

Note: For Duo-Flo units, the tee P/N 481931 and check valve P/N 81229 are sold separately.

Snap-Tite (AL) assembly  

481934

Snap-Tite (Brass) assembly  

481937

Snap-Tite (SST) assembly  

481938

Foster (Steel) assembly  

481935

Foster (Brass) assembly  

481936

Hansen (Brass) assembly  

481940

Hansen (SST) assembly  

481939

Duff-Norton assembly  

481941

Cejn assembly, locking  

481943

Snap-tite (AL) , locking  

481944

Constant-Flow Air-Line Adapter Assemblies

Constant-Flow Air-Line Adapter Assemblies

Designed to deliver the required air flow to the facepiece at an inlet pressure range of 35-40

psig for hose lengths of 8 to 300 feet. The adapters include an integral belt clip and male and

female quick-disconnect assemblies.

Quick-Disconnect  

Duo-Twin  

Duo-Flo

Snap-Tite (AL) assembly  

483526  

466077

Snap-Tite (Brass) assembly  

483530  

476919

Snap-Tite (SST) assembly  

483531  

476920

Foster (Steel) assembly  

483528  

469869

Foster (Brass) assembly  

483532  

476918

Hansen (Brass) assembly  

483529  

476922

Hansen (SST) assembly  

 483533  

476921

Duff-Norton assembly  

483534  

476923

Cejn assembly, locking  

483535  

479114

Snap-Tite (AL), locking  

483536  

479115

Fax: (773) 538-8080

Telephone: (800) 275-8239                        Website: www.supersafety.com     page 32