SELF-CONTAINED BREATHING APPARATUS [BACK]  [NEXT]

Emergency Breathing Systems

The Quick-Fill® System

The patented Quick-Fill System lets MSA Air Mask users refill and transfill air cylinders while the SCBA is worn, without removing the air cylinder—even in IDLH atmospheres. Use this MSA-exclusive option to:

• Fill an SCBA cylinder from a mobile compressor or cascade system in less than a minute.

• Transfill between two cylinders, providing an Emergency Breathing System.

• Extend the air supply over longer durations, using a remote compressed-air source.

Because performance is not affected, MSA Air Masks retain NIOSH certification during use of the Quick-Fill System.

The Quick-Fill System uses a special adapter assembly. On beltmounted

units, it’s located on the regulator, while MMR units

have a junction block and fitting installed on the gauge line. Air

Masks compliant to NFPA-1981, 2002 Edition have the Quick-Fill

URC fitting located at the Audi-Larm warning device. A Quick-Fill

hose with a quick-disconnect connects the air source to the

adapter for air transfer. See Bulletin 0105-92-MC for a Question

& Answer overview of Quick-Fill Systems.

Quick-Fill Hoses

25-ft lengths are stocked; other "custom lengths" are available on a special material basis. All SAE Fittings are for high-pressure service. Female quick-disconnect fittings have dust covers.

  

25 ft  

12 ft  

10 ft  

8 ft  

6 ft  

3 ft

FQD x FQD  

485332  

802690  

802689  

802688  

802687  

485331

FQD x CGA-347 Outlet  

487907  

802677  

802675  

802673  

802671  

492796

FQD x CGA-347 CN  

487909  

802685  

802683  

802681  

802679  

487427

FQD x SAE-4  

487906  

802704  

802703  

802702  

802701  

802705

FQD x CGA-346 Outlet  

487908  

802678  

802676  

802674  

802672  

492797

FQD x CGA-346 CN  

487910  

802686  

802684  

802682  

802680  

487428

The Quick-Fill System

Low-Pressure MMR Quick-Fill Kit (shoulder) for units purchased after 12/98  

10020382

High-Pressure MMR Quick-Fill Kit (shoulder) for units purchased after 12/98  

10020383

Quick-Fill adapter block only for shoulder-mounted units purchased after 12/98  

10020515

Low-Pressure MMR Quick-Fill Kit (shoulder) for units purchased before 12/98  

495172

High-Pressure MMR Quick-Fill Kit (shoulder) for units purchased before 12/98  

495173

Quick-Fill Kit for ICM, Low-Pressure (excluding 3000 psig)  

10020382

Quick-Fill Kit for ICM, High-Pressure  

10020383

Quick-Fill adapter only for ICM (less coupling)  

10020515

Replacement Parts for the Quick-Fill System

EBS hose package, includes 3-foot emergency transfill hose in Kevlar pouch  

485366

Emergency transfill hose, less Kevlar pouch  

485331

Kevlar pouch  

485390

Male stainless steel quick-disconnect with SAE-10 thread, complete with dust cover (also for use as a fitting for customized refilling systems)  

485391

Female quick-disconnect with SAE-4 thread, complete with dust cover  

485392

RescueAireII

Portable Air-Supply System

The RescueAire II Portable Air Supply System is

designed to meet the needs of Rapid Intervention

Teams (RITs). The system consists of a lightweight

Carbon-Wrapped cylinder, Quick-Fill® emergency

breathing system, ExtendAire™ emergency breathing

system, and an MMR regulator, supported by a

flame- and heat-resistant harness. The RescueAire

is a complete system that can provide emergency

breathing air for most any victim.

The RescueAire II System is available in both lowpressure

(2216 psig) and high-pressure (4500 psig)

versions. An optional-use shoulder strap is also

provided for hands-free carrying.

 

RescueAire™ II Portable Air-Supply System

Low-Pressure (2216 psig)  

 with L-30 cylinder  

less cylinder

RescueAire II with L-30 Cylinder  

10025491  

 10033312

RescueAire II, Firehawk STC MMR  

10041196  

10041198

RescueAire II, Firehawk PTC MMR  

10041230  

 10041232

High-Pressure (4500 psig)  

 with L-60 cylinder  

less cylinder

RescueAire II with H-60 Cylinder  

10025462  

 10025492

RescueAire II, Firehawk STC MMR  

10041195  

 10041197

RescueAire II, Firehawk PTC MMR  

 10041199  

10041231

The ExtendAireSystem   

The ExtendAire System can be used as both an

emergency breathing system and a dual-purpose

device for MMR SCBA to allow firefighters to

quickly and easily connect to an air-line.

The ExtendAire™ System
ExtendAire Air-line Hose with foster plug    812958
40" Rescue Hose   812973
ExtendAire Upgrade Kit for Threaded Firehawk MMR   10031798
ExtendAire Upgrade Kit for Quick-Connect Firehawk MMR   10031797

Fax: (773) 538-8080

Telephone: (800) 275-8239                        Website: www.supersafety.com     page 51